Search This Blog
Capacitor and Types of Capacitors
Bearing and Types of Bearings
- To reduce friction between moving rotatory parts.
- To support rotating parts of a machine.
- To bear radial and thrust load
Measuring and Types of Measuring Tools
Metal and Types of Metals
Spring and Types of springs
A Mechanical Spring is a device that can also be defined as an elastic or resilient member, whose main function is to deflect under the action of load and recovers it’s original shape when the load is removed. It also used for storing energy.
Sprocket and Types of sprockets
Rivet and Types of Rivets
What is rivet?
Washer and Types of washers
Fastener and Types of Fasteners
Material of a Fastener are :
Drill Bit and Types of Drill Bits
What is Pump and types of pump ?
What is a Pump?
A Pump is a mechanical device that uses to transfer different fluids from one location to another. It is a hydraulic device that lifts fluids from low to high levels, and moves fluids from low to high-pressure areas. The pump transfers fluid by converting the fluid’s mechanical energy into pressure energy (hydraulic energy).
Types of Pump
1. Positive Displacement Pump
2. Reciprocating Pumps
3.Rotary Pump
4. Pneumatic Pump
5.Dynamic Pump
6.Centrifugal Pumps
7.Vertical Centrifugal Pumps
PSM alam 2 and SPM alarm 59
How to reset PSM ( Power supply module) alarm no 2 and SPM ( Spindle amplifier module) alarm no 59 ?
Remedy:- Check for PSM internal cooling fan if it is not working then this alarm will come,Replaced PSM internal cooling fan
PSM internal cooling fan show in above Picture
Fan motor stop alarm
Remedy:- Check HMI cooling fan motor for work condition if found faulty replaced otherwise Cooling fan remove or reinsert
Spindle serial link error alarm
Description: This alarm is generated when the spindle control unit is not ready for starting correctly when the power is turned on in the system with the serial spindle. The four reasons can be considered as follows:
An improperly connected optical cable or the spindle control unit’s power is OFF.
When the NC power was turned on under alarm conditions other than SU–01 or AL–24 which are shown on the LED display of the spindle control unit. In this case, turn the spindle amplifier power off once and perform startup again.
Other reasons (improper combination of hardware) This alarm does not occur after the system including the spindle control unit is activated.
The second spindle (when SP2, bit 4 of parameter No. 3701, is 1) is in one of the above conditions 1to 3). See diagnostic display No. 409 for details.
432 X AXIS CNV LOW VOLTAGE CONTROL ALARM
1. X Axis control voltage low alarm
Remedy:- 1. Check alarm on Power supply module (PSM) if got alarm no 6 on PSM check PSM cooling fan if found cooling fan is faulty ,Replaced the PSM cooling fan otherwise remove and reinsert
2. Replaced PSM fuse
2. SPN 1 S- Spindle error alarm
Remedy:-
1.Check Spindle module working condition, In display light should be glow
2. Check cooling fan of PSM or Spindle module should be working