Search This Blog

9031 SPN 1 MOTOR LOCK OR V-SIG LOS ALARM


Problem: SPN1 motor lock or V-sig Los alarm

This type of alarm comes when there is single phasing in the spindle motor.

Remedy: 

1. Check  resistance of spindle motor should be balanced.

Example: Spindle motor resistance: -

RY-0.8 ohm,YB-0.8 ohm,BR-0.8 ohm.

2. Check spindle motor wires for loose connection or brunt.

3. Check input voltage of machine should be RY,YB & BR phase 200VAC.
 


In the picture above, the spindle motor wire is burnt due to SPN1 motor lock or V signal loss alarm occurred 