Search This Blog

1850 GRID SHIFT PARAMETER


Grid shift is a parameter that moves the axis, a determined amount to a home loaction. Jumping grid happens when the machine jumps to the next pulse from the feedback system

Valid data range 0 to 99999999A grid shift is set for each axis

To shift the reference position, the grid can be shifted by the amount set inthis parameter. Up to the maximum value counted by the referencecounter can be specified as the grid shift

Note:
When this parameter has been set, the power must beturned off before operation is continued