Tool Magazine Reference Procedure in Fanuc control oi-MC

1. All Emergency Push button should be released 

2. Press Control ON push button 

3. Should be No any alarm display in massage screen 

4. Press REFERENCE key

5. Press FEED ON key

6. Press 4th axis ( Some machine 5th axis) key

7. Press + or - key